<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Archives of Rehabilitation</title>
<title_fa>مجله توانبخشی</title_fa>
<short_title>jrehab</short_title>
<subject>Medical Sciences</subject>
<web_url>http://rehabilitationj.uswr.ac.ir</web_url>
<journal_hbi_system_id>55</journal_hbi_system_id>
<journal_hbi_system_user>journal55</journal_hbi_system_user>
<journal_id_issn>2538-6247</journal_id_issn>
<journal_id_issn_online>2538-6247</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.32598/rj</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1391</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2012</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>13</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>اندازه‌گیری زاویه کوادریسپس توسط روش جدید و مقایسه آن با روش متداول گونیامتری و روش مرجع رادیوگرافی در مردان سالم</title_fa>
	<title>Measuring the Quadriceps Angle by a New Method and Comparison with Goniometer and Radiography</title>
	<subject_fa>فیزیوتراپی</subject_fa>
	<subject>Physical Therapy</subject>
	<content_type_fa>پژوهشی</content_type_fa>
	<content_type>Original</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;هدف: &lt;/strong&gt;هدف این مطالعه کاستن از خطای اندازه گیری زاویه کوادریسپس به روش رایج گونیامتری با استفاده از دستگاه و روش جدیدی است که در دانشگاه علوم بهزیستی و توانبخشی ارتقاء یافته است.&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; 40 مرد با 80 زانوی سالم در این مطالعه متدولوژیک مورد بررسی قرار گرفتند. اجرای طرح و جمع آوری داده ها توسط یک آزمونگر که طراح و سازنده دستگاه و روش جدید نیز می باشد انجام شد. زاویه کوادریسپس برای هر دو پای مردان شرکت کننده با سه روش رادیوگرافی، گونیامتری و روش جدید، اندازه‌گیری شد. روایی و پایایی دستگاه و روش جدید در مقابل روش رایج گونیامتری با در نظر گرفتن اندازه زاویه در روش مرجع رادیوگرافی مورد سنجش قرار گرفت. محاسبه ICC و آزمون‌های کولموگروف-اسمیرنوف، تی زوج و کرولی ماکلی جهت آنالیز داده‌ها بکار رفت.&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;یافته‌ها:&lt;/strong&gt; تکرار پذیری مطلق و نسبی برای اندازه گیری زاویه کوادریسپس بین روش جدید و رادیوگرافی ۰/۹۳۵ شد، در صورتیکه این مقایسه برای روش گونیامتری عدد ۰/۶۹۶ محاسبه شد. ICC بین سه بار اندازه گیری با روش جدید ۰/۹۷۴ محاسبه شد.&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;نتیجه‌گیری:&lt;/strong&gt; ارتباط بسیار قوی بین نتایج حاصل از روش جدید نسبت به رادیوگرافی بدست آمد، در صورتی که نتایج گونیامتری ارتباط ضعیف‌تری با رادیوگرافی داشت. تکرار پذیری در روش جدید با حفظ شرایط مطالعه، بسیار خوب بوده و لذا می‌توان این روش را به عنوان روشی نو در اندازه‌گیری اینگونه زوایا به کار برد.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p dir=&quot;ltr&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Objective:&lt;/strong&gt; The purpose of this study is to decrease the amount of error when measuring Q–angles using a goniometer by the new method, a private system developed at the I.R&amp;#39s university of social welfare &amp; rehabilitation sciences (USWR) by Investigator.&lt;/p&gt;

&lt;p dir=&quot;ltr&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Materials &amp; Methods:&lt;/strong&gt; Fourty subjects with Eighty healthy knees participated in this methodologic study. One investigator participated in data collection who is a licensed physical therapist and has over 6 years of clinical experience in orthopedic physical therapy. He has designed and experienced with new method and computer program. Quadriceps angles measured bilaterally for 40 subjects were recorded. Reliability and validity with new method of the measurements were calculated with Intraclass Correlation Coefficient (ICC) &amp; Repeated Measurement for new method and compared it&amp;#39s result with goniometry in contrast with radiography.&lt;/p&gt;

&lt;p dir=&quot;ltr&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Results:&lt;/strong&gt; The ICC for measuring Q-angle with a new method versus the radiography was 0.935, while the ICC for measuring Q-angle with the goniometry versus the radiography was 0.696. The ICC between measures three times obtained with a New Method was 0.974.&lt;/p&gt;

&lt;p dir=&quot;ltr&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; There is a high association between measures of Q-angle obtained with a new method compared to those obtained with radiography while this association for goniometry is low. Intratester reliability for new method is good and this method can applied as a good measurement method of Q angle.&lt;/p&gt;
</abstract>
	<keyword_fa>زاویه کوادریسپس , اندازه گیری , رادیوگرافی , گونیامتری </keyword_fa>
	<keyword>Q–angle, Measurement, Radiography, Goniometry</keyword>
	<start_page>64</start_page>
	<end_page>73</end_page>
	<web_url>http://rehabilitationj.uswr.ac.ir/browse.php?a_code=A-10-581-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Yahya</first_name>
	<middle_name></middle_name>
	<last_name>Sokhangouei</last_name>
	<suffix></suffix>
	<first_name_fa>یحیی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سجنگویی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>University of Social Welfare &amp; Rehabilitation Sciences</affiliation>
	<affiliation_fa>دانشگاه علوم بهزیستی و توانبخشی</affiliation_fa>
	 </author>


	<author>
	<first_name>Iraj</first_name>
	<middle_name></middle_name>
	<last_name>Abdollahi</last_name>
	<suffix></suffix>
	<first_name_fa>ایرج</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عبداللهی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>abdollahi@uswr.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>University of Social Welfare &amp; Rehabilitation Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>دانشگاه علوم بهزیستی و توانبخشی، تهران، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Mahmood</first_name>
	<middle_name></middle_name>
	<last_name>Kazem-Dokht</last_name>
	<suffix></suffix>
	<first_name_fa>محمود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کاظم‌دخت</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>University of Social Welfare &amp; Rehabilitation Sciences</affiliation>
	<affiliation_fa>دانشگاه علوم بهزیستی و توانبخشی</affiliation_fa>
	 </author>


	<author>
	<first_name>Masoud</first_name>
	<middle_name></middle_name>
	<last_name>Karimlou</last_name>
	<suffix></suffix>
	<first_name_fa>مسعود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کریملو</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>University of Social Welfare &amp; Rehabilitation Sciences</affiliation>
	<affiliation_fa>دانشگاه علوم بهزیستی و توانبخشی</affiliation_fa>
	 </author>


	<author>
	<first_name>Zahedeh</first_name>
	<middle_name></middle_name>
	<last_name>Khanlari</last_name>
	<suffix></suffix>
	<first_name_fa>زاهده</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>خانلری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation> Islamic Azad University, Karaj Branch</affiliation>
	<affiliation_fa>دانشگاه آزاد اسلامی، واحد کرج</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
