<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Archives of Rehabilitation</title>
<title_fa>مجله توانبخشی</title_fa>
<short_title>jrehab</short_title>
<subject>Medical Sciences</subject>
<web_url>http://rehabilitationj.uswr.ac.ir</web_url>
<journal_hbi_system_id>55</journal_hbi_system_id>
<journal_hbi_system_user>journal55</journal_hbi_system_user>
<journal_id_issn>2538-6247</journal_id_issn>
<journal_id_issn_online>2538-6247</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.32598/rj</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1391</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2012</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<volume>13</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی پایایی اولتراسونوگرافی توان‌بخشی و ارتباط بین اندازه‌گیری خطی و اندازه‌گیری سطح مقطع عضلات مولتی فیدوس کمری در افراد سالم</title_fa>
	<title>The Intrarater Reliability of Rehabilitation Ultrasonography and Linear and Cross Sectional Measurements of the Lumbar Multifidus Muscles in Normal Subjects</title>
	<subject_fa>فیزیوتراپی</subject_fa>
	<subject>Physical Therapy</subject>
	<content_type_fa>پژوهشی</content_type_fa>
	<content_type>Original</content_type>
	<abstract_fa>&lt;p style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;&lt;font face=&quot;Times New Roman&quot; size=&quot;3&quot;&gt; &lt;/font&gt;هدف:&lt;/strong&gt; استفاده از اولتراسونوگرافی توانبخشی امروزه در کلینیک‌های فیزیوتراپی کشورهای پیشرفته در حال گسترش است. به همین لحاظ توجه به تکرارپذیری تصاویر سونوگرافی بدست آمده توسط فیزیوتراپیستها و همینطور روش‌های مورد استفاده در ارزیابی اندازه عضلات از اهمیت خاصی برخوردار است. این مطالعه به منظور ارزیابی تکرارپذیری و ارتباط بین دو روش اندازه‌گیری سطح مقطع و روش خطی برای تعیین اندازه عضلات مولتی فیدوس کمری با استفاده از تصاویر سونوگرافی تهیه شده توسط فیزیوتراپیست تازه آموزش دیده طراحی شده است.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; تصویر سونوگرافی عضلات مولتی فیدوس دو طرفه سطوح &lt;span dir=&quot;LTR&quot;&gt;L2&lt;/span&gt; تا &lt;span dir=&quot;LTR&quot;&gt;L5&lt;/span&gt; کمری 60 داوطلب خانم سالم ثبت شد. سپس سطح مقطع عضلات مولتی فیدوس با دو روش 1) رسم حاشیه عضله و محاسبه سطح درون حاشیه رسم شده، و 2) روش خطی رسم قطرهای طرفی و قدامی-خلفی و ضرب این قطرها در یکدیگر محاسبه شد. تکرارپذیری داده‌ها نیز در یک مطالعه موازی با حضور 16 داوطلب سالم و اندازه‌گیری‌های فوق در دو جلسه متوالی بررسی گردید.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;یافته‌ها:&lt;/strong&gt; پایایی معناداری بین دو جلسه ارزیابی برای هر دو روش اندازه‌گیری خطی و سطح مقطع در تمام سطوح مهره‌های کمری مشاهده گردید (ICC=0/81-0/98). ارتباط معناداری بین دو روش سطح مقطع و خطی برای تعیین اندازه عضلات مولتی فیدوس کمری یافت شد (r=0/89-0/97, P&lt;0/0001).&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;نتیجه‌گیری:&lt;/strong&gt; این یافته‌ها نشان داد که استفاده از سونوگرافی توانبخشی و روش‌های ارزیابی خطی در کلینیک‌های فیزیوتراپی روش مؤثری برای ارزیابی اندازه و تغییرات عضله مولتی فیدوس کمری در برنامه‌های توانبخشی است.&lt;/p&gt;

&lt;p style=&quot;text-align: justify&quot;&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p dir=&quot;ltr&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Objective:&lt;/strong&gt; Using rehabilitation ultrasonography imaging (RUSI) is widely growing in the physiotherapy clinics of developed countries. Due to this new application, it is necessary to consider the repeatability of this new technique by novice physiotherapists and applied methods to measure the muscle size. This study has been designed to investigate the intrarater reliability and also the relation between multiplying linear dimension (MLD) and cross sectional area (CSA) measurements to evaluate the size of lumbar multifidus muscles by novice physiotherapists.&lt;/p&gt;

&lt;p dir=&quot;ltr&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Materials &amp; Methods:&lt;/strong&gt; Ultrasonographic images of L2 to L5 lumbar multifidus muscles of sixty healthy female volunteer were taken bilaterally. Then, the size of multifidus was calculated by CSA and also by MLD methods for all level of lumbar region. The repeatability of data was also evaluated in a parallel study on a group of sixteen healthy female subjects in two different evaluation sessions.&lt;/p&gt;

&lt;p dir=&quot;ltr&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Results: &lt;/strong&gt;Significant intrarater reliability was found between recoded data from two different evaluation sessions for both CSA and MLD measurements (ICC= 0.81 to 0.98). The results also indicated a significant relation was also found between CSA and MLD methods to evaluate the size of multifidus muscles for the L2 to L5 lumbar vertebra (r=0.89 to 0.97, P&lt;0.0001).&lt;/p&gt;

&lt;p dir=&quot;ltr&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Conclusion: &lt;/strong&gt;Our findings confirm that using RUSI and the MLD method are efficient methods to evaluate the size and any other change in the lumbar multifidus muscle, during rehabilitation protocols.&lt;/p&gt;
</abstract>
	<keyword_fa>مولتی فیدوس, سطح مقطع, اندازه‌گیری خطی, اولتراسونوگرافی </keyword_fa>
	<keyword>Multifidus, Cross-sectional area, Multiplying linear dimension, Ultrasonography</keyword>
	<start_page>41</start_page>
	<end_page>49</end_page>
	<web_url>http://rehabilitationj.uswr.ac.ir/browse.php?a_code=A-10-752-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Maryam Sadat</first_name>
	<middle_name></middle_name>
	<last_name>Lari-Baqqal</last_name>
	<suffix></suffix>
	<first_name_fa>مریم‌‌‌سادات</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>لاری‌بقال</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Amir Houshang</first_name>
	<middle_name></middle_name>
	<last_name>Bakhtiari</last_name>
	<suffix></suffix>
	<first_name_fa>امیرهوشنگ</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بختیاری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>amirbakhtiary@sem-ums.ac.ir</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Semnan University of Medical Sciences, Semnan, Iran.</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی سمنان، سمنان، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Rozita</first_name>
	<middle_name></middle_name>
	<last_name>Hedayati</last_name>
	<suffix></suffix>
	<first_name_fa>رزیتا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>هدایتی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Asghar</first_name>
	<middle_name></middle_name>
	<last_name>Reza-Soltani </last_name>
	<suffix></suffix>
	<first_name_fa>اصغر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رضاسلطانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Raheb</first_name>
	<middle_name></middle_name>
	<last_name>Ghorbani</last_name>
	<suffix></suffix>
	<first_name_fa>راهب</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>قربانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
