<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Archives of Rehabilitation</title>
<title_fa>مجله توانبخشی</title_fa>
<short_title>jrehab</short_title>
<subject>Medical Sciences</subject>
<web_url>http://rehabilitationj.uswr.ac.ir</web_url>
<journal_hbi_system_id>55</journal_hbi_system_id>
<journal_hbi_system_user>journal55</journal_hbi_system_user>
<journal_id_issn>2538-6247</journal_id_issn>
<journal_id_issn_online>2538-6247</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.32598/rj</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1385</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2006</year>
	<month>7</month>
	<day>1</day>
</pubdate>
<volume>7</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی تکرار پذیری اندازه‌گیری قدرت عضلات فلکسور و اکستانسور گردن توسط دستگاه ایزومتر 2</title_fa>
	<title>The Reliability of Isometer 2 Device in Measuring of Cervical Flexor and Extensor Muscles Strength</title>
	<subject_fa>عمومى</subject_fa>
	<subject>General</subject>
	<content_type_fa>پژوهشی</content_type_fa>
	<content_type>Original</content_type>
	<abstract_fa>&lt;p align=&quot;justify&quot;&gt;&lt;strong&gt;هدف:&lt;/strong&gt; با کمک وسیله اندازه‌گیری قدرت عضله می‌توان نیروی یک گروه عضلانی را اندازه‌گیری کرد. از طرف دیگر برای تعیین اثرات برنامه‌های درمانی و یا آموزشی به روشهایی با قابلیت تکرارپذیری صحیح و قابل استناد نیاز می‌باشد. هدف ازاین مطالعه تعیین میزان تکرارپذیری مقادیر اندازه‌گیری شده قدرت ایزومتریک عضلات گردن بوسیله دستگاه ایزومتر2 بود.&lt;/p&gt;

&lt;p align=&quot;justify&quot;&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; در یک مطالعه تحلیلی 37 فرد سالم غیر ورزشکار (18 مرد و 19 زن بین سنین 25-18سال) با انتخاب تصادفی در این مطالعه شرکت کردند. از یک Load Cell جدید که بر روی دستگاه قدیم نصب شده بود استفاده شد. قدرت ایزومتریکی عضلات فلکسور و اکستنسور گردن در زمانها و روزهای متفاوت و بکمک دو تست کننده با استفاده از وسیله جدید (دستگاه ایزومتر2) اندازه‌گیری شد.&lt;strong&gt; &lt;/strong&gt;&lt;/p&gt;

&lt;p align=&quot;justify&quot;&gt;&lt;strong&gt;یافته‌ها:&lt;/strong&gt; نتایج تکرارپذیری در تست‌های Inter-rater ،test-retest inter-trial  نشان‌دهنده (N1/5&lt;sw&lt;2 .=&quot;&quot; 0=&quot;&quot; p=&quot;&quot;&gt;0/001) قدرت عضلات فلکسور و اکستنسور گردن در زنان به ترتیب 1/46% و 8/30% نسبت به مردان بود. &lt;/sw&lt;2&gt;&lt;/p&gt;

&lt;p align=&quot;justify&quot;&gt;&lt;strong&gt;نتیجه‌گیری:&lt;/strong&gt; در این مطالعه ما از دستگاه جدیدتری (ایزومتر 2) نسبت به دستگاه قدیمی (ایزومتر) استفاده کردیم.. انداره گیریهای قدرت ایزومتریک عضلات گردن که بوسیله دستگاه ایزومتر2 بدست آمد بصورت یک روش مفید برای اندازه‌گیری قدرت عضلات فلکسور و اکستنسورگردن ظاهر گردید.&lt;/p&gt;

&lt;p align=&quot;justify&quot;&gt; &lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p dir=&quot;ltr&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Objective:&lt;/strong&gt; The strength of a group of muscles can be measured by muscle strength test, employing a force measuring instrument. In order to monitor the effectiveness of a therapeutic or training programs we need a reliable technique which is also accurate in repeated measurements. The purpose of this study was to examine the reliability of an isometric neck muscle force measurement device.&lt;strong&gt; &lt;/strong&gt;&lt;/p&gt;

&lt;p dir=&quot;ltr&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Materials &amp; Methods:&lt;/strong&gt; Thirty seven healthy non athlete subjects (18 males and 19 females, aged 18-25) participated in this analytical study. The maximal isometric contractions of the neck extensor and flexor muscles were measured in different times and different days and by two different testers. A new sensitive “load cell” was applied to our previously designed neck muscle force measurement apparatus.&lt;/p&gt;

&lt;p dir=&quot;ltr&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Results:&lt;/strong&gt; The results of the inter-trail, test retest, and inter rater reliability (0.86 &lt; ICC &lt; 0.98 , 2.2&lt; Sw &lt;5.1 N) indicated that the neck muscle force measurements were highly repeatable and less variable between measurements. There were no statistically significant differences in neck muscle force measurements, between times, between days and between retsters. Maximum isometric contractions were significantly higher in males than in the females (p &lt; 0.001). Women’s neck muscle strengths were 30.8% and 46.1% of men in cervical extension and cervical flexion.&lt;/p&gt;

&lt;p dir=&quot;ltr&quot; style=&quot;text-align: justify&quot;&gt;&lt;strong&gt;Conclusion:&lt;/strong&gt; In this study we used a new model (Isometer 2) of our previous apparatus (Isometer). The isometric strength of neck flexor and extensor muscles which was measured by Isometer 2 appeared to be a reliable and useful method for measuring the force of the neck extensor and flexor muscles.&lt;/p&gt;
</abstract>
	<keyword_fa>قابلیت تکرارپذیری, ایزومتریک, گردن, نیرو</keyword_fa>
	<keyword>Reliability, Isometric, Neck muscles, Flexor, Extensor</keyword>
	<start_page>6</start_page>
	<end_page>11</end_page>
	<web_url>http://rehabilitationj.uswr.ac.ir/browse.php?a_code=A-10-1-41&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Asghar Reza</first_name>
	<middle_name></middle_name>
	<last_name>Soltan-Zadeh</last_name>
	<suffix></suffix>
	<first_name_fa>اصغررضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سلطان‌زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>E-mail: arezasoltani@yahoo.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Physiotherapy, School of Rehabilitation, Shahid Beheshti Unuversiti of Medical Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>گروه فیزیوتراپی، دانشکده توانبخشی، دانشگاه علوم پزشکی و خدماتبهداشتی درمانی شهید بهشتی، تهران، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Amir</first_name>
	<middle_name></middle_name>
	<last_name>Ahmadi</last_name>
	<suffix></suffix>
	<first_name_fa>امیر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>احمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Delshad</first_name>
	<middle_name></middle_name>
	<last_name>Emami</last_name>
	<suffix></suffix>
	<first_name_fa>دلشاد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>امامی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Seyyed Taha</first_name>
	<middle_name></middle_name>
	<last_name>Lajevardi</last_name>
	<suffix></suffix>
	<first_name_fa>سیدطه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>لاجوردی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Farshad</first_name>
	<middle_name></middle_name>
	<last_name>Okhovatian</last_name>
	<suffix></suffix>
	<first_name_fa>فرشاد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>اخوتیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
