<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Archives of Rehabilitation</title>
<title_fa>مجله توانبخشی</title_fa>
<short_title>jrehab</short_title>
<subject>Medical Sciences</subject>
<web_url>http://rehabilitationj.uswr.ac.ir</web_url>
<journal_hbi_system_id>55</journal_hbi_system_id>
<journal_hbi_system_user>journal55</journal_hbi_system_user>
<journal_id_issn>2538-6247</journal_id_issn>
<journal_id_issn_online>2538-6247</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.32598/rj</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1404</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2025</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>26</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تأثیر کفی تراشیده‌شده بر متغیرهای کینماتیکی راه رفتن در افراد دارای اختلاف طول اندام تحتانی</title_fa>
	<title>Impact of a Milled Insole on Kinematic Gait Parameters in People With Mild Structural Leg Length Discrepancy</title>
	<subject_fa>اورتز و پروتز</subject_fa>
	<subject>Orthotics &amp; Prosthetics</subject>
	<content_type_fa>كاربردی</content_type_fa>
	<content_type>Applicable</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;strong&gt;هدف &lt;/strong&gt;اختلاف طول در اندام تحتانی یکی از شایع&#8204;ترین مشکلات اسکلتی&#8204;عضلانی است که تأثیر بسزایی بر راه رفتن دارد. مداخلات ارتوزی معمولاً در اختلاف طول&#8204;های ساختاری تا 50 میلی&#8204;متر کاربرد دارند. عمدتاً کفی و لیفت پاشنه به&#8204;عنوان مداخلاتی کم&#8204;تهاجم، جهت جبران اختلاف طول ساختاری خفیف در اندام&#8204;های تحتانی پیشنهاد می&#8204;شوند. هدف از این مطالعه بررسی تأثیر کفی اختصاصی تراشیده&#8204;شده از جنس اتیلن&#8204;وینیل&#8204;استات بر متغیرهای کینماتیکی راه رفتن در افراد دارای اختلاف طول ساختاری کمتر از 20 میلی&#8204;متر در اندام تحتانی است.&lt;br&gt;
&lt;strong&gt;روش &lt;/strong&gt;بررسی این مطالعه شبه&#8204;تجربی بر روی 15 فرد با میانگین سنی 23 سال، دارای اختلاف &#8204;طول ساختاری از بدو تولد در اندام &#8204;تحتانی انجام شد. تغییرات مربوط به متغیرهای کینماتیکی پلویک، هیپ، زانو و مچ با دستگاه ارزیابی حرکت و صفحه&#8204; فشاری با و بدون کفی ثبت شد. داده&#8204;های ثبت&#8204;شده با آزمون آماری تی &#8204;زوجی در نرم&#8204;افزار SPSS تجزیه&#8204;و&#8204;تحلیل شد. سطح معنی&#8204;داری 0/05 در نظر گرفته شد.&lt;br&gt;
&lt;strong&gt;یافته&#8204;ها &lt;/strong&gt;در این مطالعه شاهد تغییر معنادار میانگین دامنه حرکت زانوی پای&#8204; کوتاه&#8204;تر در صفحه فرونتال (P=0/03)، مچ پای &#8204;بلند&#8204;تر در صفحه ساجیتال (P=0/02) و مچ پای&#8204; کوتاه&#8204;تر در صفحه فرونتال (P&lt;0/01) حین فاز ایستایی بودیم. حین فاز نوسانی نیز میانگین دامنه حرکت زانوی پای&#8204; کوتاه&amp;lrm;&#8204;تر در صفحه ساجیتال (P=0/02) و مچ پای&#8204; کوتاه&#8204;تر در صفحه فرونتال (P&lt;0/01) تغییر معناداری را تجربه کرد.&lt;br&gt;
&lt;strong&gt;نتیجه&#8204;گیری &lt;/strong&gt;کفی تراشیده، باعث بهبود متغیرهای دامنه حرکت زانوی پای&#8204; کوتاه&#8204;تر در صفحه فرونتال، میانگین دامنه حرکت مچ پای &#8204;بلند&#8204;تر در صفحه ساجیتال و میانگین دامنه حرکت مچ پای&#8204; کوتاه&#8204;تر در صفحه فرونتال حین فاز ایستایی شد. در فاز نوسانی نیز میانگین دامنه حرکت زانوی پای&#8204; کوتاه&amp;lrm;&#8204;تر در صفحه ساجیتال و میانگین دامنه حرکت مچ پای&#8204; کوتاه&#8204;تر در صفحه فرونتال بهبود یافت. این تغییرات می&#8204;تواند نشانگر تأثیر مثبت کفی اصلاح&#8204;کننده اختلاف&#8204; طول بر متغیرهای راه رفتن باشد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;

&lt;div&gt;&lt;div id=&quot;ftn1&quot;&gt;&lt;/div&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;strong&gt;Objective &lt;/strong&gt;Leg length discrepancy (LLD) is one of the most common musculoskeletal conditions, significantly affecting gait. Orthotic interventions are used for mild structural LLDs up to 50 mm, such as heel lifts and insoles, as minimally invasive interventions. This study aims to evaluate the effect of CNC-milled ethylene-vinyl acetate (EVA) insoles on kinematic gait variables in individuals with structural LLD &lt;20 mm.&lt;br&gt;
&lt;strong&gt;Materials &amp; Methods&lt;/strong&gt; This quasi-experimental study was conducted on 15 individuals with a mean age of 23 years, who had mild congenital structural LLD. The insole was manufactured from EVA foam using a CNC milling machine. It was covered with synthetic leather. Changes in pelvic, hip, knee, and ankle kinematic variables were recorded using a motion analysis system and pressure plate, with and without the insole. The data were analyzed in SPSS software, version 23 using paired t-test or Wilcoxon signed-rank test, considering a significance level of P&lt;0.05.&lt;br&gt;
&lt;strong&gt;Results &lt;/strong&gt;Significant changes were observed in the knee range of motion (ROM) of the shorter leg on the frontal plane (P=0.03), ankle ROM of the longer leg on the sagittal plane (P=0.02), and ankle ROM of the shorter leg on the frontal plane (P&lt;0.001) after using the insole during the stance phase of gait. During the swing phase, significant changes were reported in the knee ROM of the shorter leg on the sagittal plane (P=0.02) and the ankle ROM of the shorter leg on the frontal plane (P&lt;0.001). The maximum ankle inversion angle of both legs (P=0.04 for shorter leg, P=0.02 for longer leg), the maximum ankle eversion angle of the longer leg (P=0.04), and the maximum ankle internal rotation angle of the longer leg (P=0.04) also showed a significant increase after using the insole during the stance phase.&lt;br&gt;
&lt;strong&gt;Conclusion &lt;/strong&gt;The milled insole can improve some kinematic gait parameters in people with mild congenital structural LLD.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>اختلاف‌ طول اندام ‌تحتانی, کفی, کینماتیک, راه رفتن</keyword_fa>
	<keyword>Leg length discrepancy (LLD), Orthotic insole, Kinematics, Gait</keyword>
	<start_page>380</start_page>
	<end_page>397</end_page>
	<web_url>http://rehabilitationj.uswr.ac.ir/browse.php?a_code=A-10-3988-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>omid</first_name>
	<middle_name></middle_name>
	<last_name>omidi</last_name>
	<suffix></suffix>
	<first_name_fa>امید</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>امیدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>omid.omidi5593@gmail.com</email>
	<code></code>
	<orcid>0009-0000-4056-8651</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Orthotics and Prosthetics, School of Rehabilitation Sciences, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>گروه ارتوز و پروتز، دانشکده علوم توانبخشی، دانشگاه علوم توانبخشی و سلامت اجتماعی، تهران، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>akbar</first_name>
	<middle_name></middle_name>
	<last_name>Biglarian</last_name>
	<suffix></suffix>
	<first_name_fa>اکبر</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بیگلربان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>abiglarian@gmail.com</email>
	<code></code>
	<orcid>0000-0002-9776-7085</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Biostatics and Epidemiology, Social Determinants of Health Research Center, School of Social Health, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>گروه آمار زیستی و اپیدمیولوژی، مرکز تحقیقات عوامل اجتماعی مؤثر بر سلامت، دانشکده سلامت اجتماعی، دانشگاه علوم توانبخشی و سلامت اجتماعی، تهران، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Zhaleh</first_name>
	<middle_name></middle_name>
	<last_name>Heydari</last_name>
	<suffix></suffix>
	<first_name_fa>ژاله</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حیدری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>dr.zhalehheydari@gmail.com</email>
	<code></code>
	<orcid>0000-0003-0837-1378</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Rehabilitation and Medical Science, Iran-helal Institute of Applied Science and Technology, Tehran, Iran.</affiliation>
	<affiliation_fa>گروه علوم توانبخشی و پزشکی، موسسه علوم و فناوری کاربردی هلال ایران، تهران، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>roshanak</first_name>
	<middle_name></middle_name>
	<last_name>Baghaie Rodsari</last_name>
	<suffix></suffix>
	<first_name_fa>روشنک</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بقایی رودسری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>roshanakbaghaei@yahoo.com</email>
	<code></code>
	<orcid>0000-0001-6572-5959</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Orthotics and Prosthetics, School of Rehabilitation Sciences, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>گروه ارتوز و پروتز، دانشکده علوم توانبخشی، دانشگاه علوم توانبخشی و سلامت اجتماعی، تهران، ایران.</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
