<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Archives of Rehabilitation</title>
<title_fa>مجله توانبخشی</title_fa>
<short_title>jrehab</short_title>
<subject>Medical Sciences</subject>
<web_url>http://rehabilitationj.uswr.ac.ir</web_url>
<journal_hbi_system_id>55</journal_hbi_system_id>
<journal_hbi_system_user>journal55</journal_hbi_system_user>
<journal_id_issn>2538-6247</journal_id_issn>
<journal_id_issn_online>2538-6247</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.32598/rj</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1404</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2025</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>26</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تأثیر پد ضد‌اصطکاک اسپندکس بر رضایتمندی، درد، تعادل و توانایی راه رفتن در افراد آمپوته زیر زانوی یک‌طرفه: مطالعه پایلوت</title_fa>
	<title>The Effect of Spandex Anti-friction Pad on Satisfaction, Pain, Balance, and Walking in Unilateral Transtibial Amputees: A Pilot Study</title>
	<subject_fa>اورتز و پروتز</subject_fa>
	<subject>Orthotics &amp; Prosthetics</subject>
	<content_type_fa>پژوهشی</content_type_fa>
	<content_type>Original</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;strong&gt;هدف &lt;/strong&gt;در سوکت هیبرید زیر&#8204;زانو کماکان بخش کمی از وزن توسط تاندون پتلا تحمل می&#8204;شود. پد ضد&#8204;اصطکاک متشکل از 2 لایه پارچه است که ضریب اصطکاک بین آن دو نزدیک به صفر است و می&#8204;تواند تا حدودی فشار&#8204;های روی ناحیه کشکک را کاهش دهد. در این مطالعه تلاش شده تا تأثیر استفاده از پد ضد&#8204;اصطکاک اسپندکس همراه با سوکت هیبرید زیر زانو را بر میزان توانایی راه رفتن، رضایتمندی، تعادل و کاهش درد در ناحیه اطراف کشکک و تاندون پاتلار بررسی شود.&amp;nbsp;&lt;br&gt;
&lt;strong&gt;روش &lt;/strong&gt;بررسی 16 نفر آمپوته زیرزانو که از سوکت طرح هیبریدی استفاده می&#8204;کردند و با معیارهای مطالعه مطابقت داشتند، به&#8204;صورت دردسترس وارد مطالعه شدند. متغیرهای مطالعه شامل مدت&#8204;زمان ایستادن روی پای پروتزی، مدت&#8204;زمان راه رفتن روی تردمیل با سرعت 4 کیلومتر بر ساعت، میزان درد (با مقیاس VAS) و رضایتمندی (OPUS) بررسی شدند. سپس شرکت&#8204;کنندگان به مدت 1 هفته از پد اسپندکس در سوکت پروتزی خود استفاده کردند. پس از 1 هفته متغیرهای مطالعه مجدداً ارزیابی شدند. جهت آزمون نرمال بودن توزیع داده&#8204;های آماری از آزمون کولموگروف اسمیرنف استفاده شد. برای آنالیز داده&#8204;هایی که از توزیع نرمال تبعیت می&#8204;کردند (رضایتمندی و مدت&#8204;زمان راه رفتن روی تردمیل) از تی زوجی و برای داده&#8204;هایی که فاقد توزیع نرمال بودند (درد و مدت&#8204;زمان ایستادن روی پای پروتزی) آزمون ویلکاکسون استفاده شد. جهت آنالیز داده&#8204;ها از نرم&#8204;افزار SPSS نسخه 26 استفاده شد.&lt;br&gt;
&lt;strong&gt;یافته&#8204;ها&lt;/strong&gt; در این مطالعه، تفاوت معناداری در متغیرهای مورد&#8204;مطالعه یعنی افزایش رضایتمندی(P&lt;0/001)، کاهش معنادار درد پوست ناحیه تاندون پتلا (P&lt;0/001)، توانایی ایستادن روی یک پا (P&lt;0/001) و تأثیر قابل&#8204;توجهی در توانایی راه رفتن روی تردمیل (P&lt;0/001)، بعد از 1 هفته استفاده از پد ضد&#8204;اصطکاک اسپندکس نسبت به قبل از استفاده مشاهده شد.&amp;nbsp;&lt;br&gt;
&lt;strong&gt;نتیجه&#8204;گیری &lt;/strong&gt;نتایج مطالعه حاضر نشان داد استفاده از پد ضد&#8204;اصطکاک اسپندکس با هدف کاهش فشار و اصطکاک بین سوکت و استمپ در ناحیه تاندون پاتلار، موجب کاهش درد در این ناحیه و افزایش رضایتمندی و راحتی کاربران پروتز زیر&#8204;زانو که در این ناحیه دچار مشکل هستند، می&#8204;شود. از&#8204;این&#8204;رو به نظر می&#8204;رسد با کمک پد ضد&#8204;اصطکاک اسپندکس کاربران پروتز زیر&#8204;زانو قادر باشند مسافت بیشتری راه بروند و سطح عملکرد آن&#8204;ها افزایش یابد، اما برای اثبات این امر نیاز به بررسی بر روی کاربران بیشتری است.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;div&gt;&lt;/div&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify; margin-bottom: 11px;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:Tahoma;&quot;&gt;&lt;strong&gt;Objective &lt;/strong&gt;In transtibial hybrid sockets, a small amount of weight is tolerated by the patellar tendon. The spandex anti-friction pad is designed with two fabric layers that minimize the friction between them; therefore, its use may reduce the pressure on the patellar tendon in transtibial amputees. In this study, we aim to evaluate the effect of using spandex anti-friction pad within a transtibial hybrid socket on the standing and walking duration, satisfaction, and pain in the patellar tendon of unilateral transtibial amputees (UTTAs).&amp;nbsp;&lt;br&gt;
&lt;strong&gt;Materials &amp; Methods&lt;/strong&gt; In this pilot study, 16 eligible UTTAs using the hybrid sockets were selected using a convenience sampling method. The duration of standing on the prosthetic leg (using the one-leg standing balance test [OLSTP]), the duration of walking on the treadmill, pain (using the VAS), and satisfaction with the prosthetic leg (using the orthotics and prosthetics user&amp;rsquo;s survey [OPUS]) were examined. Then, the participants used the anti-friction pad within their prosthetic sockets for one week. After that, the post-test assessments were conducted. The paired t-test was used for comparing variables with normal distribution (OPUS score and duration of walking on the treadmill) and the Wilcoxon test was used for those with abnormal distribution (VAS and OLSTP scores). The SPSS software, version 26 was used to analyze the data.&lt;br&gt;
&lt;strong&gt;Results &lt;/strong&gt;The participants showed a significant reduction in VAS score (P&lt;0.001) and a significant increase in the OPUS score (P&lt;0.001) after using the anti-friction pad. Moreover, the results showed a significant effect on increasing the OLSTP score (P&lt;0.001) and the duration of walking on the treadmill (P&lt;0.001).&lt;br&gt;
&lt;strong&gt;Conclusion &lt;/strong&gt;The use of spandex anti-friction pad, for reducing the pressure and friction between the socket and the stump, may reduce pain and increase the satisfaction and comfort of transtibial prosthesis users. It can also help them walk greater distances and stand on their prosthetic leg longer. However, to confirm these findings, further studies are needed.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</abstract>
	<keyword_fa>درد, پروتز زیر‌زانو, قطع عضو زیر زانو, پد ضد‌اصطکاک اسپندکس​​​​​​​</keyword_fa>
	<keyword>Pain, Transtibial prosthesis, Transtibial amputee, Anti-friction pad</keyword>
	<start_page>344</start_page>
	<end_page>359</end_page>
	<web_url>http://rehabilitationj.uswr.ac.ir/browse.php?a_code=A-10-1705-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Erfan</first_name>
	<middle_name></middle_name>
	<last_name>Abolhasani</last_name>
	<suffix></suffix>
	<first_name_fa>عرفان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ابوالحسنی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>erfan.oandp@gmail.com</email>
	<code></code>
	<orcid>0009-0003-7270-7494</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Karaj Red Crescent Society Rehabilitation Center, Alborz Province Red Crescent Society, Karaj, Iran.</affiliation>
	<affiliation_fa>مرکز توانبخشی جمعیت هلال احمر کرج، جمعیت هلال احمر استان البرز، کرج، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Gholamreza</first_name>
	<middle_name></middle_name>
	<last_name>Aminian</last_name>
	<suffix></suffix>
	<first_name_fa>غلامرضا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>امینیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>gholamrezaaminian@yahoo.com</email>
	<code></code>
	<orcid>0000-0002-7977-4695</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Orthotics and Prosthetics, School of Rehabilitation Sciences, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>گروه ارتوز و پروتز، دانشکده توانبخشی، دانشگاه علوم توانبخشی و سلامت اجتماعی، تهران، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Roshanak</first_name>
	<middle_name></middle_name>
	<last_name>Baghaei Roodsari</last_name>
	<suffix></suffix>
	<first_name_fa>روشنک</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بقایی رودسری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>roshanakbaghaei@yahoo.com</email>
	<code></code>
	<orcid>0000-0001-6572-5959</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Orthotics and Prosthetics, School of Rehabilitation Sciences, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran.</affiliation>
	<affiliation_fa>گروه ارتوز و پروتز، دانشکده توانبخشی، دانشگاه علوم توانبخشی و سلامت اجتماعی، تهران، ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Zahra</first_name>
	<middle_name></middle_name>
	<last_name>Jiryaei Sharahi</last_name>
	<suffix></suffix>
	<first_name_fa>زهرا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جیریایی شراهی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>jiryaei.z@gmail.com</email>
	<code></code>
	<orcid>0000-0002-1222-8163</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Orthotics and Prosthetics, Iran-Helal Institute of Applied Science and Technology, Tehran, Iran.</affiliation>
	<affiliation_fa>گروه ارتوز و پروتز، مؤسسه علمی‌کاربردی هلال احمر، تهران، ایران.</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
