Volume 13, Issue 2 (Summer 2012)                   Vol. , No. , Season & Year , Serial No. | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Sokhangouei Y, Abdollahi I, Kazem-Dokht M, Karimlou M, Khanlari Z. Measuring the Quadriceps Angle by a New Method and Comparison with Goniometer and Radiography. jrehab. 2012; 13 (2) :64-73
URL: http://rehabilitationj.uswr.ac.ir/article-1-998-en.html
1- Assistant Professor University of Social Welfare & Rehabilitation Sciences
2- Assistant Professor University of Social Welfare & Rehabilitation Sciences, Tehran, Iran. , abdollahi@uswr.ac.ir
3- MSc of Physical Therapy University of Social Welfare & Rehabilitation Sciences
4- Biostatistician, Associate Professor University of Social Welfare & Rehabilitation Sciences
5- MSc of Physical Education and Sport Sciences Islamic Azad University, Karaj Branch
Abstract:   (9039 Views)

Objective: The purpose of this study is to decrease the amount of error when measuring Q–angles using a goniometer by the new method, a private system developed at the I.R's university of social welfare & rehabilitation sciences (USWR) by Investigator.

Materials & Methods: Fourty subjects with Eighty healthy knees participated in this methodologic study. One investigator participated in data collection who is a licensed physical therapist and has over 6 years of clinical experience in orthopedic physical therapy. He has designed and experienced with new method and computer program. Quadriceps angles measured bilaterally for 40 subjects were recorded. Reliability and validity with new method of the measurements were calculated with Intraclass Correlation Coefficient (ICC) & Repeated Measurement for new method and compared it's result with goniometry in contrast with radiography.

Results: The ICC for measuring Q-angle with a new method versus the radiography was 0.935, while the ICC for measuring Q-angle with the goniometry versus the radiography was 0.696. The ICC between measures three times obtained with a New Method was 0.974.

Conclusion: There is a high association between measures of Q-angle obtained with a new method compared to those obtained with radiography while this association for goniometry is low. Intratester reliability for new method is good and this method can applied as a good measurement method of Q angle.

Full-Text [PDF 476 kb]   (1072 Downloads)    
Type of Study: Original | Subject: Physical Therapy
Received: 2/01/2012 | Accepted: 10/03/2013 | Published: 10/03/2013

Add your comments about this article : Your username or Email:
Write the security code in the box

Send email to the article author


© 2015 All Rights Reserved | Archives of Rehabilitation

Designed & Developed by : Yektaweb